60 days refund
E-commerce since 2007

Contactors

Filter
Sorting
Schneider Electric Acti9 iCT Contactor (230V 25A) 2NO
22,75 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Contactor (230-400V/25A) 4 Pole NO
(6)
46,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D18B7 (Coil 24V-18A)
54,49 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
ABB Contactor (400V, 25A) 4-Pole NO
31,60 EUR
Add to cart
In stock
Delivery: 1 weekday
Siemens Auxiliary Contact Module 1NC
7,99 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Acti9 Contactor (230V 16A) 1NO-1NC
33,49 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Acti9 iCT Contactor (230V, 25A) 4NO
32,99 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D12P7 (Coil 230V-12A)
48,29 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Acti9 Contactor iCT (230V-25A) 1NO
25,49 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D09P7 440V (Coil 230V-9A)
46,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D09B7 (Coil 24V-9A)
56,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Auxiliary Contact Block for Contactor - 1NO/1NC
21,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Auxiliary Block for Contactor - 2NO-2NC
26,79 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Black Connection Handle for Combi (5SU)
26,79 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Earth Leakage Circuit Breaker
18,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D12B7 (Coil 24V-12A)
48,29 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LP1K0901BD 440V (Coil 24V-9A)
47,75 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Auxiliary Contact Block (2NO-2NC)
17,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Contactor (4kW/400V) 24V - 1NO
38,39 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens 3-Phase Busbar for 3 Contactors, 45mm
14,69 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens 3-Phase Busbar for 5 Contactors, 45mm
18,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens 3-Phase 4-Pole Busbar (45mm)
15,99 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Contactor (3kW/400V) 24V - 1NO
36,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Contactor (230V, 20A) 2NO
53,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Nulelement VZ-12 Safety Switch - 1NO
22,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Contactor (5.5kW/400V) 24V - 1NO
45,59 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Auxiliary Block for Contactor - 2NO
18,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Siemens Auxiliary Contact (1NO-1NC)
12,19 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Contactor LC1D09BL (Coil 24V-9A)
55,89 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026
Schneider Electric Interconnection Module (GV2MELC1D)
10,25 EUR
Add to cart
Remote storage
Delivery: 2-4 weekdays
Latest: 27. November 2026

Contactor - For controlling high current via lower current

Here on the site, you will find our selection of contactors that can be used to control a large current with a small current.

For example, if you have an electric motor that needs to be started or stopped with electrical control, you can use a contactor to control the current.

The contactor is very similar to a relay in the way it is used, but the contactor is better at connecting a larger current than a relay, and this is because the contacts in a contactor move significantly faster than the contacts in a relay.

A contactor consists of an electromagnet, an armature, a spring, and one or more contact sets, and when current is sent through the coil, or the winding of the electromagnet, the armature is attracted by the magnetic field.

One side of the contact set is attached to the armature and is now pulled with great force towards the other side of the contact set, when you switch off the current, the spring pulls the contact set back to neutral, with very great force and speed. 

If you are in doubt about which contactor to get, you can read below, where we have gathered some useful knowledge, which can help you find the right contactor for your needs. 

6 things you should know when looking for a contactor

There are many different models and sizes of contactors, and it can be difficult to figure out which one is the right one and what you should look for. 

Remember that if you are in doubt, you should always contact a licensed electrician and you should be aware that there may be special rules for electrical work related to the installation of the contactor. 

Read below and learn more about what you should pay attention to when looking for a new contactor.

#1 - The difference between Contactor and relay

A contactor is very similar to a relay, both in function and appearance, but while a relay has a common contact that connects to a neutral position, a contactor connects 2 poles without a common circuit.

But that is not the only difference, because a contactor can be rated for up to 1000 Volts, while a relay can usually only be rated for up to about 250 Volts. 

The contactor is like the relay an electrically controlled switch that is used to switch an electrical circuit, but a contactor is often controlled by a circuit that has a much lower power level than the switched circuit.

For example, you could mention a 24 volts coil electromagnet that controls a 230 volts motor switch.

#2 - Advantages of Contactor

There are several advantages to using a contactor and examples can include:

  • A contactor can be connected to any network
  • The contactor is compact in size
  • The contactor is silent
  • The contactor can be used for very high currents and high powers
  • A contactor is relatively easy to install and operate
  • The contactor can operate in any environment

One of the great advantages is that the contactor can switch a circuit more efficiently than, for example, a relay, and it can do this because the contacts move significantly faster and with greater strength than the relay, reducing the risk of the contact set welding together. 

#3 - Dimensions of Contactor

When you need to find the right contactor for a panel, it is important that you, in addition to the many specifications, also consider the dimensions of the contactor.

So how much space does the contactor take up in the panel, and is there room for a contactor with these dimensions? 

Contactors can vary greatly in size, and while some are small, others are large, and if you have a electric panel that is already quite full, it may be advantageous to ensure that there is actually room for the contactor. 

#4 - Coil Voltage in Contactor

The coil voltage is the voltage that the coil located in the contactor is activated with, and it is often 230V/AC standard alternating voltage.

This means that when the coil voltage is reached and the contactor activates the contact set, the contact set is pulled from one side to the other, and when the current is interrupted, the spring in the contactor ensures that the contact set quickly and powerfully returns to its starting point.

However, there are several other options for both DC and AC voltage, and the coil connection is often indicated by “A1” and “A2.”

If DC voltage is used, A1 will typically be positive and A2 typically minus, but if AC voltage is used, the connection in A1 and A2 is basically irrelevant for the function, but it is good practice to let A1 be the phase and A2 be zero.

#5 - Number of poles in Contactor

The number of poles in a contactor determines how many contact sets are activated when the coil receives voltage. 

If the contactor has, for example, 2 poles, the contactor sends electrical voltage through 2 contact sets, which are, by the way, independent of each other.

The contact sets are typically marked with numbers; 1 is above the contact set and 2 below, on the next contact set, it says 3 on top and 4 below, and so on.

Contact set 1 belongs to pole 1 and contact set 2 belongs to pole 2, but there is at no time contact between the two poles.

It is most common to use contactors with one or two poles, and somewhat less common to use 3-pole contactors.

A three-pole contactor is typically used in 3-phase AC power networks, where they are used to control powerful electric motors and other devices.

It is also possible to get contactors with many more poles, but these are often used in industry and are very rarely used.

#6 - Types of contactors

The types of contactors can be categorized in several ways, but the most common is to categorize them by the way they are controlled.

Here, there is often a distinction between a manual contactor and a low current wire contactor.

For a mechanical or manual contactor, it must be manually turned on and off, which is done using toggle switches on the outside of the contactor.

A contactor that operates using a low current wire switches itself.

However, the type of contactor can also be determined by the installation type, and here it is referred to as a houseless contactor or an encapsulated contactor.

The houseless contactor is often installed in electrical panels or electrical installations and is not on its own protected against water and dust.

An encapsulated contactor can be installed anywhere, as it is both dust and waterproof. 

ATTENTION! Your order is only binding, when we have confirmed your order.