Relays
Latest: 27. November 2026
Latest: 27. November 2026
Latest: 1. December 2026
Latest: 30. November 2026
Latest: 1. December 2026
Latest: 1. December 2026
Latest: 7. December 2026
Latest: 27. November 2026
Latest: 27. November 2026
Relay - connecting and disconnecting power
On this page, you will find our complete selection of relays that can be used for both monitoring and connecting and disconnecting power to a device.
There are many different types of relays, each with their own characteristics, but what all types have in common is that a relay connects electrical current on and off.
Types of relays can, for example, be:
- Industrial relays
- Momentary and bistable relays
- Reed relays
- Relay for DIN rail
- Power monitoring relay
- Timer and time delay relays
If you are unsure which relay you need, you can read below, where you can find some help with the different specifications for relays.
7 things you need to know when looking for a new relay
There are many different types of relays, and it can be difficult to find the right one, so it is important that you know what to look for.
Below are compiled some things that are good to know when you are looking for a new relay.
#1 - The right type of relay
First and foremost, it is important to choose the right type of relay for your project, and there are many different types to choose from.
The type often relates to the function the relay performs, and below you will see examples and characteristics of some of the types.
- Phase control relay - also called a control relay and it monitors the phase voltage in a circuit of devices in a three-phase supply network. It can prevent damage to devices when connecting and disconnecting from the network, in case of phase faults, or asymmetrical voltage.
- Control relay - also known as a contactor and is used where a large current needs to be controlled by a smaller current, e.g., for use with motor protection. For example, a motor can start and stop with the help of a control relay.
- Timer relay - opens or closes a circuit at fixed intervals or can be used to delay opening or closing of circuits.
- Time counter relay - counts the hours the relay is open and is often used in DIN panels.
As the relays have different functions, it is important that you are clear about what the relay should do to be able to choose the right relay.
#2 - Voltage and current
It is important to look at the voltage that the relay is designed for, regardless of which type of relay you are looking for.
The voltage is usually specified in a maximum voltage in volts, and in some cases, a rated voltage is also specified.
You should also be aware of whether this voltage is AC or DC voltage, i.e., alternating current or direct current.
If you use a DC relay for AC voltage, you risk damaging both the relay and the device.
You should also be aware of the current rating, which is often measured in amperes; the current rating specified on the relay must not be less than the current from your device.
#3 - Relay dimensions
Relays can have different dimensions depending on the type, so it is important to be aware of the size of the relay.
Some relays are larger than others, and even if you are replacing an older relay with a newer one of the same type, you may find that the new relay does not necessarily have the same dimensions.
Dimensions are important to pay attention to because there may often be limited space where the relay needs to be installed, and it would be unfortunate if you had to swap the relay because it is potentially too large for the available space.
#4 - IP class
Another thing you should be aware of, especially if the relay is located outdoors or in dusty areas, is the IP classification.
The IP class indicates the relay's protection against dust and liquids and is an international standard.
The IP class always consists of the letters IP followed by two numbers; sometimes there may also be a K at the end.
The first number indicates the protection against dust and dirt, and the second number indicates the protection against liquids.
The higher the number, the greater the protection, and a designation of 0 means that there is no protection for the relevant material.
Typically, a relay is not protected against liquids, so you will often see that the IP class has a 0 as the second number.
#5 - Installation of relay
When installing the new relay, you should ensure that the relay is mounted according to the instructions for the relevant relay.
Some relays are designed to be mounted in a panel, and others are designed for installation on DIN rails.
So you should consider how your relay should be mounted and find a relay that fits this.
#6 - Therefore, you should use a relay
A relay protects against fault currents that can cause electric shock or damage your connected device.
Relays can among other things be used to:
- control a high voltage circuit with a low voltage signal
- perform various functions, such as turning on and off, counting, and similar
- create sounds, for example, buzz sound upon activation
- activate, for example, locking mechanisms, etc.
Relays are used both at home and in countless businesses and have gradually become a standard component in all power systems.
It has even been mandatory since 2008 that all homes must have a relay that can interrupt power in various faults and accidents when it comes to electricity.
Without a relay, your devices at home or in the workplace are more vulnerable to power failures, fault currents, and in some cases, also lightning strikes.
#7 - How to find out if a relay needs to be replaced
When you need to find out if a relay is faulty, it is quite easy to locate the relay that isn't working with a multimeter.
First, you need to identify where the circuit goes in and out of the relay, and then you need to measure the current both in and out of the relay.
After that, check if there is power where the relay is mounted; if there is no power there, you can check the fuse.
If there is power where the relay is mounted, i.e., in the socket, you can use the multimeter's continuity function to check if there is a good ground connection on the circuit's opposite side of the relay.
If the fault is still not found, check the fuse for the circuit supplying power to the relay.
If there is still a fault, check the connection between the relay and the device with the multimeter's continuity function; if there is a connection, it may be time to replace the relay with a new one.